turbo-generators major overhauls and regular repairs in REK“Bitola” 3´225 [MW], REK “Oslomej” 125 [MW], and TPP “Negotino” 210 [MW] (HP, IP and LP turbine)
turbo-generators nominal power extending in REK “Bitola” from 3´210 [MW] to 3´225 [MW]
turbine rotor blades replacement on the Bauman’s 5 th and 6 th degree in the low pressure area and turbine rotor blades replacement on 1 st & 2 nd degree in intermediate pressure area in REK “Oslomej” 125 [MW]
turbine new slide bearings producing and old slide bearings repairing in REK “Oslomej” 125 [MW]
generator exciter repair in REK “Oslomej” and REK “Bitola”
generator coolers repair in REK “Oslomej” and REK “Bitola”
repair of oil coolers for the turbo-generator in REK “Oslomej”
high and intermediate pressure re-heaters repair (PBD, PND) in REK “Oslomej”
turbine regulation systems adjusting in REK “Bitola”, REK “Oslomej” and TPP “Negotino”
repair of feed water pumps
repair of condensate pumps
armatures & machine part revision
regular participation in repairs of the steam boilers in REK “Bitola”, REK “Oslomej” and TPP “Negotino”
repair the reheating groups of the steam boilers in REK “Bitola”, REK “Oslomej” and TPP “Negotino”
manufacturing the pipe packages of the reheating groups from the boiler in REK “Oslomej”
manufacturing of dust burner for the boiler in REK “Oslomej”
manufacturing and mounting of economizer for the boiler in REK “Oslomej”
manufacturing and mounting of separator for the boiler in REK “Oslomej”
air and smoke ventilators repair, centering and balancing in REK “Bitola”, REK “Oslomej” and TPP “Negotino”
coal mills repair in REK “Bitola” and REK “Oslomej”
reduction stations repair for steam pressure in REK “Bitola” and REK “Oslomej”
repair and manufacture the armature on the spot in REK “Bitola”, REK “Oslomej” and TPP “Negotino”
repair of feed water pumps in REK “Bitola” and REK “Oslomej”
repair of recirculation pumps in REK “Bitola”, REK “Oslomej” and TPP “Negotino”
condenser pumps repair and replacement in REK “Bitola”, REK “Oslomej” and TPP “Negotino”
air regenerative heater repair (RVP)
manufacturing of boilers pipe systems ( WB – 1,2 )
manufacturing of boiler economizer G 32
manufacturing of boilers pipe heaters G 32 I, II, III
boilers reconstruction G 32 for use of natural gas as a fuel
revision and procession of the armature on the spot
main boilers repair (WB – 1,2)
mounting of gas regulation station
reconstruction of pipe installation
revision of cooler system
repair of feeding circulation pumps